P11E - Access Code 1 (Master)
P12E - Access Code 2
P13E - Access Code 3
P14E - Access Code 4
P15E - Access Code 5
P16E - Access Code 6
P17E - Access Code 7
P18E - Access Code 8
P19E - Access Code 9
P20E - Access Code 10
P21E - Access Code 11
P22E - Access Code 12
P23E - Access Code 13
P24E - Access Code 14
P25E - Access Code 15
P26E - Entry Time 1
P27E - Entry Time 2
P28E - Exit Time
Installer Access Only
P29E - Alarm Time (Reset)
P30E - Normal Sirens
P31E - VIB SENS 1 Zones
P32E - VIB SENS 2 Zones
P33E - VIB SENS 3 Zones
P34E - VIB SENS 4 Zones
P35E - VIB SENS 5 Zones
P36E - VIB SENS 6 Zones
P37E - VIB SENS 7 Zones
P38E - VIB SENS 8 Zones
P39E - Double Trig Zones
P40E - Instant Zones
P41E - Entry 1 Zones
P42E - Handover Zones
P43E - Entry 2 Zones
P44E - Lockout Zones
P45E - Assign Area 1 Zones
P46E - Assign Area 2 Zones
P47E - Area 1 Active Codes 1-8
P48E - Area 1 Active Codes 9-15
P49E - Area 2 Active Codes 1-8
P50E - Area 2 Active Codes 9-15
P51E - Monitor Zones
P52E - 24 Hr Zones
P53E - Day Zones
P54E - Reset Output Zones
P55E - Strobe Output Zones
P56E - Sonalert Output Zones
P57E - Siren Output Zones
P58E - AL 1 Output Zones
P59E - AL 2 Output Zones
P60E - Miscellaneous
1E - Entry Warning Beeps
2E - Keyswitch Monitor Mode
3E - Keyswitch Mode
4E - Tamper Siren Lockout (On)
5E - Duress Reset Output
6E - Auto Exclude Zones
7E - Disable LED's
8E - O/P (A1 & A2) On After Exit
P61E - Tamper & Panic Outputs
1E - Tamper To Reset
2E - Tamper To Strobe
3E - Tamper To Sonalert
4E - Tamper To Siren
5E - Panic To Reset
6E - Panic To Strobe
7E - Panic To Sonalert
8E - Panic To Siren
P62E - Shortcuts
1E - Memory Display Shortcut
2E - Exclude Shortcut
3E - Monitor Arm Shortcut
4E - Medical / Fire Shortcut
5E - Area 1 Arm Shortcut
6E - Area 2 Arm Shortcut
7E - 2 Second Siren Warning Auto Exclude
8E - Exit Time x10
P63E - Day & Monitor Outputs 1E - Monitor Reset Output 2E - Monitor Strobe Output 3E - Monitor Sonalert Output 4E - Monitor Siren Output 5E - Day Reset Output 6E - Day Strobe Output 7E - Day Sonalert Output 8E - Day Siren Output
P64E - Miscellaneous 1E - 2 Second Monitor Alarm 2E - 2 Second Day Alarm 3E - Pre-Alarm Monitor
Installer Access Only
P96E - Upload From Panel
P97E - Download To Panel
P98E - Return To Default - Access Codes 1-15
P99E - Installation Code
P70E - Telephone Number 1 (Numeric Entry Only)
P71E - Telephone Number 2 (Numeric Entry Only)
P72E - Client Code 1
P73E - Client Code 2 (Used For Area 2 Open / Close)
P74E - Report Zone Alarms
P75E - Report Miscellaneous Alarms
P76E - Report Zone Alarms Restored
P77E - Report Miscellaneous Alarms Restored
P78E - Report Multiple Zone Alarms
P79E - Zone Mapping To Client Code
P80E - Telephone No. 1 (Incl, *,#, And Pause)
P81E - Telephone No. 2 (Incl, *,#, And Pause)
P82E - Area Zone Restore Reports
1E - Immediatly On Input Resealed
2E - After Siren Reset
3E - After Opening + Input Sealed
4E - After Always Opening
P83E - Time Between Test Calls (2 Hr Steps)
P84E - Time Before First Test Call (2 Hr Steps)
P85E - Dialing Method
1E - Automatic
2E - Decadis (Pulse) Dial
3E - V.F (DTMF) Dial
P86E - Miscellaneous Reporting
1E - Ademco Extended/Audible Format
2E - Enable Test Calls
3E - Delay Mains Fail By 1 Hour
4E - Ademco Extended (No Checksum)
P87E - Miscellaneous
1E - Split Dial Or Alternate
2E - Dial Without Dial Tone
3E - New Zealand Dial
4E - 4 - 10 Dial Attempts
P88E - Miscellaneous Open / Close
1E - Send Area 1 Open / Close
2E - Send Area 2 Open Close
3E - 2 Sec. Siren On Closing
4E - 2 Sec. Strobe On Closing
Enable Test Calls
1. Enable P88E 1E (Send Area 1 Open Close Reports)
2. P70E (Telephone No. 1 Primary Number)
3. P71E (Telephone No. 2 Secondary Number)
4. P72E (Client Account Number) (Default 0000)
5. P89E 1E (Enable Test Calls)
6. P86E 1E, 2E, 3E (Ademco Extended/Audible Format, Enable Test Calls, Delay Mains Fail By 1 Hour)
7. P83E (Test Call Interval) (Default 84 / 168 Hours)
8. P84E (Time Before First Test Call) (Default 6/12 Hours)