P17E - Entry Delay Time 1 (20Secs) - 15
P170E - Entry Delay Time 1 (20Secs) - 15
P171E - Entry Delay Time for AREA 1 (20Secs) - 15
P172E - Entry Delay Time for AREA 2 (20Secs) - 15
P173E - Entry Delay Time for AREA 3 (20Secs) - 15
P18E - Exit Delay Time (60Secs) - 15
P181E - Exit Delay Time for AREA 1 (60Secs) - 15
P182E - Exit Delay Time for AREA 2 (60Secs) - 15
P183E - Exit Delay Time for AREA 3 (60Secs) -15
P28E - Siren Reset Time (10Mins) - 15
P19E - Security Delay Zones (None) - 16
P20E - Instant Zones (Zoines 3-24) - 16
P21E - Entry Delay Zones (Zone 1) - 16
P22E - Handover Zones (Zone 2) - 16
P23E - Secondary Delay Zones (None) - 16
P271E - Single Trigger Zones (All Zones) - 16
P272E - Double Trigger Zones (No Zones) - 16
P251E - Zone Input Response Time(100 Milliseconds) - 17
P252E - Zone Input Response Time(200 Milliseconds) - 17
P253E - Zone Input Response Time(400 Milliseconds) - 17
P254E - Zone Input Response Time(440 Milliseconds) (All Zones) - 17
P255E - Zone Input Response Time(480 Milliseconds) - 17
P256E - Zone Input Response Time(520 Milliseconds) - 17
P257E - Zone Input Response Time(560 Milliseconds) - 17
P258E - Zone Input Response Time(600 Milliseconds) - 17
P261E - Vibration Sensitivity Extreme - 17
P262E
P263E
P264E
P265E
P266E
P267E
P268E - Vibration Sensitivity Low
P291E - Siren Lockout Zones (All Zones) - 18
P292E - Siren Lockout Tamper Alarms (All) - 18
P293E - Siren Lockout Systems Alarms (All) - 18
P294E - Siren Lockout Power Alarms (All) - 18
P301E - Excludable Zones (All Zones) -18
P302E - Excludable Tamper Alarms (All) - 18
P303E - Excludable Systems Alarms (All) - 18
P304E - Excludable Power Alarms (All) - 18
P310E - Assign Zones to ADMIN AREA (All Zones) - 19
P311E - Assign Zones to AREA 1 (None) - 19
P312E - Assign Zones to AREA 2 (None) - 19
P313E - Assign Zones to AREA 3 (None) - 19
P321E - Assign Zones to MONITOR 1 (None) - 19
P322E - Assign Zones to MONITOR 2 (None) - 19
P33E
1E - Two Button Keypad Operation (Off) - 20
2E - Shortcut ARMING (On) - 20
3E - Shortcut EXCLUDE (On) - 20
P34E
1E - Keyswitch Unrestricted Operation (Off) - 21
2E - Chirp Siren on K/S Arm/Disarm (Off) - 21
3E - No Auto Exclude (Off) - 21
4E - Entry Beeps (On) - 21
5E - (Not Used) - 21
6E - Disable Zone Tamper (On) - 21
7E - AUX 1 Armed Output (Off) - 21
8E - 'Zone Unsealed' Warning on Arming (Off) - 21
MAPPING ZONES & ALARMS TO OUTPUT GROUPS (XX=OUTPUT GROUP)
P35 xxE - Map Zones When ARMED (All Zones : P3517E) - 22
P36 xxE - Map Zones When Disarmed (All Zones : P360E) - 22
P37 xxE - Map Zones In Monitor Mode (All Zones : P3720E) - 22
P38 xxE - Map 24 Hour Zones (All Zones : P380E) - 22
P39 xxE - Map Tamper Alarms (All Zones : P3927E) -23
P40 xxE - Map Systems Alarms (Various) - 23
P41 xxE - Map Power Alarms (Various) - 23
P42 xxE 1E - Map General Purpose Timer (Disabled : P420E) - 23
CREATE INSTALLER DEFINED OUTPUT GROUPS - METHOD 1
P43 uuE yyE - Create Installer Defined Output Groups 1-15 - 25
P441E - Zones With No Exit Delay (None) - 26
P45E
1E - Installation WALK TEST (Select Zones to Test) -26
2E - Enable Auto Zone Test (Off) - 26
P50E - Client Code for Central Station (0000) - 27
P51E - Telephone Number 1, Primary (None) - 27
P52E - Telephone Number 2, Secondary (None) - 27
P53E - Telephone Number 3, Callback (None) - 27
P54E
1E - (Off) - 28
2E - Audible Voice Reporting Format (Off) - 28
3E - Contact ID Reporting Format (On) - 28
P55E
1E - Auto Dialling Pulse & DTMF (On) - 29
2E - Pulse Dialling Always (Off) - 29
3E - DTMF Dialling Always (Off) - 29
P57E
1E - Alternative Dialing Pri/Sec Phone Number (On) - 29
2E - Dial Each Telephone Number 5 Times (Off) - 29
3E - Repeat to Telephone Number 2 (Off) - 29
P58E
1E - Remote Command / Callback Option 1 (Off) - 30
2E - Remote Command / Callback Option 2 (Off) - 30
3E - Enable Remote ARM, ADMIN AREA (Off) - 30
4E - Enable Remote ARM, AREA 1 (Off) - 30
5E - Enable Remote ARM, AREA 2 (Off) - 30
6E - Enable Remote ARM, AREA 3 (Off) - 30
7E - Enable Remote Operation, AUX 1/2 (Off) - 30
8E - Enable Remote Disarm, ALL AREAS (Off) - 30
P59E - Required Rings for Auto-Answer (1) - 30
P60E
1E - Enable Open/Close Reports (On) - 30
2E - Send ADMIN. Area O/C Reports Only (Off) - 30
3E - Send Open/Close With P75xxE Client Codes (Off) - 30
4E - Disable Open/Closed Reports (Off) - 30
P61E - Map Zones to Contact ID Channels (See Page 31)
P62E - Map Tamper Alarms to Contact ID (See Page 31)
P63E - Map System Alarms to Contact ID (See Page 31)
P64E - Map Power Alarms to Contact ID (See Page 31)
P65E
1E - Disable Multiple Zone Alarm Reports (On) - 32
2E - Enable Multiple Zone Alarm Reports (Off) - 32
P66E
1E - Send Restorals After Siren Time (Off) - 32
2E - Send Restorals on Disarm (Off) - 32
3E - Send Restorals Immediately (On) - 32
4E - Do not Send Restorals (Off) - 32
P67E - Mains Fail Reporting Delay (60 Minutes) - 32
P68E - Abort Delay (30 Seconds) - 33
P69E - Abort Delay Zones (None) - 33
P70E - Time Before First Test Call (168 Hours) -33
P71E - Test Call Interview (Disabled) - 33
P72E 1E - Enable Easy Call Feature (Off) - 34
P73E - Digits to Dial After Opening (Disabled) - 34
P74E - Digits to Dial After Closing (Disabled) - 34
ALTERNATE CLIENT CODE USED WHEN P60E 3E IS ON
P750E - ADMIN. Area Client Code (0000) - 35
P751E - Area 1 Client Code (0000) - 35
P752E - Area 2 Client Code (0000) - 35
P753E - Area 3 Client Code (0000) - 35
CREATE INSTALLER DEFINED OUTPUT GROUPS - METHOD 2
P80 uuE yyE - Installer Defined Output (Groups 1-15, Outputs 1-10) - 25
P81 uuEyyE - Installer Defined Output (Groups 1-15, Outputs 11-16) - 25
P82E
1E - (Not Used) (Off) - 35
2E - Enable Dialler (On) - 35
3E - Enable Radio Interface (Off) - 35
4E - Enable Output Expander (Off) - 35
P831E - Program Radio Keys (Select Radio Key 1E - 8E) - 37
P83E - Clear Radio Keys (Select Radio Key 1E - 8E) - 37
P841E - Program Radio Devices (Select Radio Device 1E - 8E) - 37
P84E - Clear Radio Devices (Select Radio Device 1E - 8E) - 37
P85E - Supervised Radio Zones (Select Zones 1-8) - 38
P86E - Radio Supervision Time (0-24 Hours) (Disabled) - 38
P93E - Medical Delay (Disabled) - 39
P94E - General Purpose Timer Delay (Disabled) - 40
P95E - General Purpose Timer Duration (Disabled) - 40
P96E - Code Retry Limit (2) - 41
P97E - Duress Prefix (9) - 41
P981E - Default Panel Options (except Dialler, Codes & Delays) - 41
P982E - Default User Codes, Installer Codes & Entry / Exit Delay Times - 41
P983E - Default Dialler Options - 41
P984E - Clear Alarm Memory - 41
P985E - Clear Dialler Buffer - 41
P99E - Program Installer Code (000000) - 40
P + E - Exit Program Mode